Skip to content
HEY Mimarlık

Istanbul District Building Guide

Istanbul district by district: building stock, permits and site conditions

The table below gathers, on a single page, what actually makes work difficult in the Istanbul districts where we build most often. Each row comes from site experience; the detail sits in the relevant district article.

There are no prices or durations here. Both depend on the building, and a figure given without seeing it does not hold. The table carries technical findings only.

DistrictDominant building typeTechnical issuePermits / managementSite logistics
BebekWaterfront mansions, detached houses, compact flats with a viewDamp in timber frames; rising damp at basement and ground levelBosphorus law: no added floors, no roof conversion, no enclosing the gardenNo room for a crane; items split and assembled in place
LeventTower floors, plus a low-rise residential fabricCeiling void is full: ducts, sprinklers, cable traysBuilding management; fire system changes need an approved contractorGoods lift by appointment; anything larger than the car never reaches the floor
MecidiyeköyOlder commercial blocks, street-level shops, newer towersIncoming electrical capacity is tight for present-day loadsCommon areas need owners’ consent; signage needs council permissionNo daytime unloading on the avenue; night deliveries
AtaköyPlanned estate blocksIn tunnel-form blocks internal walls are structural — the plan cannot changeEstate management approval, undertaking, working-hour limitsLift cars in older blocks are small
FloryaDetached villas on garden plotsHigh water table: hydrostatic pressure in basementsEnclosed area cannot be increased; programme moves to the gardenAccess within the plot is straightforward
Bakırköy centreApartment stock from 1960–85Cast iron drainage stacks; electrics without earthingThe stack is shared: owners’ decision requiredFive-storey buildings without lifts are common
GöktürkVillas on gated estatesHeating cost of a detached house; envelope performance decides itEstate design code fixes the external envelopeFar from the centre: no second trip for a missing part
KemerburgazVillas and gardens on sloping groundWithout drainage behind retaining walls, walls failSet-back distance from the forest boundaryAll excavation work is grouped into one opening
SilivriSecond homes, detached summer housesStill air and condensation in a closed house; risk of frozen pipesDetached plots; estate rules where there is an estateRemote: decisions are gathered before work begins
ÇatalcaRural houses, farm buildings, stone and adobe village housesCement render ruins stone and adobe wallsWithout mains, water, drainage and power are planned separatelySome plots cannot take heavy vehicles
KadıköyOlder apartment stockServices at the end of their life; ceiling height is the advantageShared service decisions involve the whole buildingNarrow streets and parking problems

How to read the table

The technical issue column shows where the invisible part of the budget sits. A cast iron drainage stack or a high water table weighs far more than the choice of kitchen doors.

The permits column drives the programme. A single façade item or an estate approval can hold up the whole job, which is why we split the scope into items that need consent and items that do not.

The logistics column feeds straight into labour cost. A building without a lift, a street with no room for a crane, or a goods lift that runs by appointment move the same job to a different figure.

Where this comes from

These rows are not compiled from general industry material. They come from projects we have run in these districts and from the technical articles we publish for each one. The full set is linked from our service areas page.

Frequently asked

From projects we have run in these districts and the technical articles we publish for each one. It is not a compilation of general industry material; every row is backed by the district article where it is explained in detail.

Because they depend on the building. Age, services, permit regime and site logistics move the same floor area to very different figures. A number given without a site visit does not hold, so the table carries technical findings only.

Wall thickness and sound give a first clue but do not settle it. If the building file is available that is the clearest route; otherwise a section is exposed through an existing service duct or socket box, and rebar scanning is used where needed. We establish this before quoting.

Yes. The table covers districts for which we have published detailed technical notes; our service area is not limited to them. We work across Istanbul, in other provinces of Türkiye and abroad.

Let’s talk about what is different in your district.

Share a plan or a few photographs; we come back to you within one business day.

Request a quote

Our work on this

ALL PROJECTS →
WHATSAPP CALL GET A QUOTE

We would like to use analytics cookies to improve the site. Nothing beyond the essentials runs without your consent. Details